ERLAB® Captair Smart Filters, Options and Accessories

FLEX TECHNOLOGY – The configurable design of the filtration column makes the CaptairSmart line of ductless fume hoods adaptable to the laboratory safety needs of most applications. The interchangeability of the filters allows the filtration column to be configured specifically for the applications carried out within the hood.Screen Shot 2017-05-29 at 10.02.58 AM

1 – Air intake through the openings – Air from the laboratory enters the hood through ergonomic openings. The air face velocity creates a dynamic barrier between the user and the chemicals being handled.

Erlab Captair Catalog
ERLAB® Captair Catalog

2 – Filtration of particles and molecules – The device ventilation system draws the particles and any molecules that have evaporated in the hood toward the filtration system. The level of containment provided by the hood prevents any pollutants from being released into the laboratory.

3 – Clean air into the laboratory – The filtration technology customized to the application traps the molecules that have evaporated within the enclosure. The discharged air is free from all pollutants.

4 – Purification of the ambient air – The continuous recirculation of the filtered air helps to purify the ambient air of the laboratory.

Type of filters :

AS: For organic vapours
BE+: Polyvalent for acid + organic vapours
F: For formaldehyde vapours
K: For ammonia vapours
Type of filters :

HEPA H14:99.995 % efficiency filtration of particles over 0.1 μm in size
ULPA U17:99.999995 % efficiency filtration of particles over 0.1 μm in size
Type of Molecode sensors :

S : for organic vapours
A : for acids
F : for formaldehyde
Filters, Options and Accessories for your ERLAB® CaptairSmart Filtered Fume Hood

Captair Flex S 321 GF4 Spec                Captair Flex S 321 GF4 Spec                Captair Flex S 321 GF4 Spec                Captair Flex S 321 GF4 Spec Screen Shot 2017-05-29 at 10.05.58 AM

Captair Flex S 321 GF4 Spec                  Pre-filter                Durcon_BlackOnyx                 Tempered Glass Work Surfac Screen Shot 2017-05-29 at 10.29.05 AM

            Replacement of HEPA Filter Procedure                Erlab Filtration HALO System                Erlab Filtration Halo Smart System

Replacement of HEPA Filter Procedure   ERLAB® HALO Filtration System   ERLAB® HALO Smart Filtration System

Molecode Product Image                Molecode Product Image                Molecode Product Image                Transparent back panel
Screen Shot 2017-05-29 at 10.06.45 AM

Molecode S Setting Manual                   Molecode M & R settings checklist

           Molecode S                                         Molecode A & F

Captair without Molecode Captair with Molecode

       Captair without Molecode                                                           Captair with Molecode

 

BenchCap Screen Shot 2017-05-29 at 10.29.51 AM  MobiCap

Flex Mobicap Assembly       Assembly benchcap